Description
Operating Range
- Pressure: 15 to 150 PSI (1,0 to 10,3 bar)
- Flow: 0.2 to 30 GPM (0,05 to 6,82 m³/h; 0,01 to 1,89 l/s); for flows below 3 GPM (0,68 m³/h; 0,19 l/s) or any Xerigation® application, use a 200 mesh filter installed upstream
- Operating Temperatures:
Water temperature up to 110° F (43° C); ambient temperature up to 125° F (52° C)
Electrical Specifications
- 24 VAC 50/60 Hz (cycles/sec.) solenoid
- Inrush current: 0.290 A at 60 Hz
- Holding current: 0.091 A at 60 Hz
- Coil resistance: 70-85 Ohms (40° F – 110° F)
Dimensions
- Height: 4.62 inches (11,7 cm)
- Height (MB): 4.50 inches (11,43 cm)
- Length: 4.4 inches (11,2 cm)
- Length (MB): 5.68 inches (14,4 cm)
- Width: 3.1 inches (7,9 cm)
Recommendations
- Rain Bird recommends flow rates that result in discharge velocities in the supply line not to exceed 7.5 ft/sec (2.3 m/s) in order to reduce the effects of water hammer.
- Rain Bird residential valves cannot be used with PRS pressure regulating modules.
- Not recommended for use with two-wire systems.
HV and HVF Valve Pressure Loss
Flow (gpm) |
1 inches HV (psi) |
Male x Barb (psi) |
1 | 1.57 | 1.73 |
3 | 2.07 | 2.06 |
5 | 2.38 | 2.25 |
10 | 3.33 | 2.80 |
20 | 4.59 | 4.45 |
30 | 6.14 | 7.85 |
40 | 8.23 | 13.68 |
HV and HVF Valve Pressure Loss (Metric)
Flow (m3/h) |
Flow (l/s) |
1 inches HV (bar) |
Male x Barb (bar) |
0,25 | 0,06 | 0,11 | 0,12 |
0,75 | 0,21 | 0,14 | 0,14 |
1,00 | 0,28 | 0,16 | 0,16 |
2,00 | 0,56 | 0,23 | 0,19 |
5,00 | 1,39 | 0,32 | 0,31 |
7,50 | 2,08 | 0,42 | 0,54 |
9,10 | 2,52 | 0,57 | 0,94 |